Tel. (877) 630-3762

SERIE 5 Advanced Chargers

Product Intro
Serie 5 represents the “Advanced” conventional Wa ranges, aimed for specific markets
demanding structured or dedicated characteristics. This series features programmable board
with internal memory, enhanced algorithms and USB (setting/troubleshooting/data-report).
The integrated digital display permits the complete controlling, programming and diagnostic
in real time. Security features involves both mechanical and software solutions.

Suitable Batteries
PzS wet lead acid

Main Applications

Specs
STANDARD AVAILABLE SIZES
PhVac
1Ph120
208-240
3Ph208-240-440-480
600
Output Voltage
2436487280
from 40 to 60 Afrom 25 to 40 Afrom 20 to 30 A////
from 80 to 160 Afrom 50 to 140 Afrom 50 to 120 A////
from 80 to 200 Afrom 80 to 200 Afrom 80 to 160 Afrom 80 to 140 Afrom 80 to 120 A
from 80 to 200 Afrom 80 to 200 Afrom 80 to 160 Afrom 80 to 140 Afrom 80 to 120 A
AH RECHARGE TABLE
A>>>20A25A30A40A50A60A80A
Ah (C6)8h103128154206257308411
12-14h132-147165-184198-220265-294331-367397-441529-588
A>>>100A120A140A160A180A200A
Ah (C6)8h5146177198229251028
12-14h661-735794-882926-10291058-11761190-13221323-1469
GENERAL CHARACTERISTICS
Mains1phase 120Vac ±5%; 208-240Vac ± 5% 60Hz 3phase 208-240-440-480Vac ±5% 60Hz
Visual signalling5 LED advanced visualization + integrated DISPLAY for programming, diagnostic, and consulting data storage
Main features• Automatic start, charging process and shutoff
• Universal Electronic Board with advanced digital setting by display: profile thresholds/ termination mode/equalization mode/delay start/cable compensation
• Final charging stage (adjustable in respect of bettery usage): temporal, capacitive (CF% and AH accumulated), derivative dv/dt
• Leakage power transformer: taper charger
• Wa charging profile (DIN 41774)
Operating temperature+32° to +104° F (0° to +40° C) no derating (heavy climate version available)
Efficiency82/88% depending on power involved
CertificationsCSA
SAFETY FEATURES
Output protectionReverse polarity protection: fuse
Thermal protectionLeakage power transformer (class F) provided with thermal probes
General protectionDouble security timer: gassing point/max charging duration; additional thermal protection based on algorithm managed by electronic board; battery detection with safety powering
MECHANICAL CHARACTERISTICS
Protection degreeIP 21
WeightDepending on model size
Input CableNot supplied
Output Cables2.7 yd (2.5 m) +/-10% (length) – DC plug on demand
Dimensions (LxWxH)I2C: 21.85 x 17.91 x 35.43 inches
P6C: 19.29 x 11.02 x 2.20 inches I2C P6C
STD FEATURES/OPTIONALS
ADVANCED LINESERIE 5
Integrated display🗸
Multiple input selection🗸
Cable holder🗸
USB portOn Demand
Protection cageOn Demand